Siglent SAP1000H: 1 GHz differential active probe, ±42 V range, 10X/50X, 1 pF / 200 kΩ input, SAPBus-powered. For SDS5000X HD, SDS6000 Pro and SDS7000A.

Home › Accessories › Active probes › SAP1000H
1 GHz high-voltage differential active probe · SAPBus

SAP1000H — 1 GHz differential probing up to ±42 V

The SAP1000H is a differential active probe for switching circuits where both speed and voltage matter: DC to 1 GHz, a rise time under 350 ps, and a ±42 V differential window at 50X (±8.4 V at 10X) with offset over the same range. Its 1 pF, 200 kΩ input leaves gate-drive loops, half-bridge switch nodes and DC-DC converters undisturbed.

It plugs into the SAPBus interface of the SDS5000X HD, SDS6000 Pro and SDS7000A. The oscilloscope powers the probe and reads its model, serial number, bandwidth, impedance, capacitance and attenuation automatically, so the vertical scale is right from the first connection. Differential and common-mode offset compensation are set from the scope’s probe menu, and the optional EA0210 attenuator extends the range to ±60 V without giving up bandwidth.

DC–1 GHz · < 350 ps 10X ±8.4 V · 50X ±42 V 1 pF · 200 kΩ differential SAPBus · scope-powered
Siglent SAP1000H differential probe on a power board

Why the SAP1000H

Siglent SAP1000H: 1 GHz with only 1 pF

1 GHz with only 1 pF

DC to 1 GHz and a rise time under 350 ps, through a 1 pF / 200 kΩ differential input. The switch node sees the probe as almost nothing, so the edge you measure is the edge the circuit produces.

Siglent SAP1000H: 42 V differential window

±42 V differential window

Two attenuation settings: 10X for ±8.4 V and 50X for ±42 V of differential signal, with offset over the same range. Gate drives, low-voltage bus switching and 24 V systems fit without an external divider.

Siglent SAP1000H: Powered and recognised by the scope

Powered and recognised by the scope

The SAPBus interface powers the probe and tells the oscilloscope its model, serial number, bandwidth, impedance, capacitance and attenuation. No supply, no batteries, no manual probe factor.

Siglent SAP1000H: A complete connection kit

A complete connection kit

Straight, pogo and swivel tips, Y-lead adapter, SMD and chip clips, pin headers, solder-in and flex leads, spring-loaded grounds, a PP201 positioner and silver wire all ship in the box.

Who it is for and where it fits

The SAP1000H sits between Siglent’s low-voltage differential probes (SAP2500D and up: a few volts of range at multi-GHz bandwidth) and the high-voltage differential probes of the DPB5000 family (hundreds of volts at 100–200 MHz). It is the probe for the middle ground: tens of volts, switching in nanoseconds. Gate-drive waveforms on SiC and GaN stages, 12–24 V bus converters, motor-drive logic, battery-management and automotive 12/24/48 V electronics fall inside its ±42 V window, and 1 GHz is enough to see ringing, dead time and dv/dt as they really are.

Ideal for
  • Power-electronics engineers on SiC / GaN gate drives and switch nodes
  • DC-DC converter and point-of-load design up to 24 V (48 V with the EA0210)
  • Automotive and battery-management electronics (12 / 24 / 48 V)
  • Motor-drive and inverter control boards
  • Labs running the SDS5000X HD, SDS6000 Pro or SDS7000A
Before you order
  • ±42 V is the differential window at 50X; the absolute limit of either input to the ground socket is ±60 V (±12 V at 10X). Mains and high-voltage DC links need a DPB5000-class probe.
  • The probe needs a SAPBus input: SDS5000X HD, SDS6000 Pro or SDS7000A. It does not work on a BNC channel or on other oscilloscope brands.
  • 1 GHz is the probe figure and the system figure on the SDS5000X HD; on a faster scope the probe sets the limit.
  • Common-mode signals are not displayed, only rejected: > 50 dB to 5 MHz, > 20 dB at 250 MHz.

Specifications

Probe typeHigh-voltage differential active probe, SAPBus interface
Bandwidth (probe only)DC to 1 GHz
System bandwidth1 GHz on the SDS5000X HD
Rise time (10–90%)< 350 ps
Attenuation (DC)10X / 50X, selectable
Input dynamic range±8.4 V (10X) · ±42 V (50X)
Offset range±8.4 V (10X) · ±42 V (50X)
Maximum input voltage (to ground socket)±12 V (10X) · ±60 V (50X), DC + peak AC
Differential input resistance200 kΩ
Single-ended input resistance100 kΩ
Differential input capacitance1 pF
DC gain accuracy / offset accuracy< 3% / < 3%
CMRR> 50 dB at 100 kHz and 5 MHz · > 20 dB at 250 MHz
With external attenuator EA0210 (option)20X / 100X · ±60 V dynamic range · ±90 V maximum · 400 kΩ · 1.8 pF · still 1 GHz
Probe head / tip pitch100 × 12 × 10 mm · 2.54 mm
Cable length130 cm, head to SAPBus box (115 × 38.9 × 24.5 mm)
Operating temperature5 °C to 40 °C, indoor use
Compatible oscilloscopesSDS5000X HD, SDS6000 Pro and SDS7000A with the SAPBus interface
Warranty1 year (probes and accessories)

From the SAP1000H User Manual EN01B. Specifications apply after 20 minutes of warm-up at 25 ± 5 °C; errors and omissions excepted.

Siglent SAP1000H probe with its standard accessories

In the box

The SAP1000H ships as a complete kit. Standard accessories:

  • Straight tips ×5
  • Pogo tips ×5
  • Swivel tips ×2
  • Tip savers ×2
  • Y lead adapters ×2
  • Micro SMD clip
  • Chip clips, black and red
  • Pin headers ×2
  • Right-angle pin lead 5 cm
  • Straight pin leads 6 cm and 12 cm
  • Spring-loaded grounds, short ×2 and long ×2
  • Solder-in leads ×2
  • Channel ID clips (4 colours)
  • Two-legged positioner PP201
  • Flex adapters, square-pin and solder-in, short and long
  • Silver wire, 1 m

Compatible oscilloscopes

Any Siglent oscilloscope with the SAPBus probe interface. The scope powers the probe and reads its parameters automatically.

Optional accessories
  • EA0210 external attenuator — 2X: extends the range to ±60 V (20X/100X) at the same 1 GHz; select “EA0210” in the probe menu, the scope cannot detect it
  • SAP1H-AB accessory kit — Replacement tips, leads, clips and grounds
  • PP301 3D positioner — Hands-free probing on a bench arm
  • PP201 two-legged positioner — Spare for the one supplied

Ask us to add positioners, the attenuator or a spare accessory kit to your order.

1 GHz differential probing for your power stage

Tell us the oscilloscope and the voltages you work with. We will confirm the SAP1000H fits, or point you to the DPB5000 range or the SAP2500D if it does not.