SYN64-R — one trigger, 64 outputs, 30 ps skew
The SYN64-R is the trigger backbone of a multi-oscilloscope acquisition system. It takes a synchronization signal on one of four inputs and fans it out to 64 SMA outputs with 1 ps typical jitter and 30 ps typical skew, so a rack of SDS6000L units, each contributing 4 or 8 channels, triggers as one instrument: up to 512 synchronised channels, with the sample clocks locked by daisy-chaining the 10 MHz references.
Compared with the original SYN64 it adds what large systems kept asking for: four selectable inputs, a real trigger engine with edge and pulse-width conditions, menu-set levels and hold-off, per-group output delay and polarity to compensate cable lengths, and remote control over LAN or USB with a browser interface, all from a 1U rack housing on a 9–15 V adapter.
What the SYN64-R does

1 : 64 fan-out, 1 ps jitter
One trigger in, sixty-four aligned copies out on SMA: 800 mVpp into 50 Ω, rise time ≤ 500 ps, 1 ps typical jitter and 30 ps typical skew between channels over the full temperature range.

Four inputs, a real trigger engine
Four 50 Ω inputs (±10 V, 0.5–20 Vpp, DC or AC coupled). Trigger on a rising or falling edge or on a positive or negative pulse width, with a ±10 V level, hold-off by time (3.2 ns to 30 s) or by event count, and a Force button for a manual pulse.

Per-group delay and polarity
The 64 outputs form eight groups of eight. Each group has its own polarity and delay: up to 3 ns in 10 ps steps in Buff mode, or up to 30 s in 7 ps steps in Normal mode, so cable-length differences across a rack are dialled out in the distributor.

LAN, USB and a web interface
LXI-style control over Gigabit LAN or USBTMC with SCPI, a browser interface for the trigger and output settings, a temperature monitor and a 1U rack housing powered from the supplied 9–15 V adapter.
Building a 512-channel system
Each SDS6000L unit brings 4 or 8 channels at up to 2 GHz and 5 GSa/s in a 1U housing with no screen. The SYN64-R supplies the common trigger: its outputs go to the external trigger input of every unit, the 10 MHz Out of one unit feeds the 10 MHz In of the next so all sample clocks run from one reference, and a network switch connects every unit and the distributor to the host.
From the host, SCPI, LabVIEW and IVI drivers address each oscilloscope individually over Gigabit LAN, while the SYN64-R’s own LAN or USB interface sets the trigger source, condition, level, hold-off and the delay of each output group. Because the delay is adjustable in 10 ps steps per group, differences in trigger-cable length across the rack are corrected in the distributor rather than in post-processing.
- 64 units × 8 channels = 512 synchronised channels from one SYN64-R
- Sample clocks locked through the daisy-chained 10 MHz reference
- Outputs are standard 800 mVpp pulses into 50 Ω, usable by any instrument with a 50 Ω trigger input

How to connect it
One signal goes in, a copy goes to every oscilloscope. Three sets of cables make the system: the synchronization signal, the network and, if you want one common sample clock, the 10 MHz reference.
Redrawn from the connection diagram in the SYN64-R data sheet. On a phone, swipe the diagram sideways.
Feed the synchronization signal in
Connect the trigger or clock pulse that starts the measurement to one of the four SMA inputs and select that input as the source. The input is 50 Ω, accepts −10 to +10 V with a swing of 0.5 to 20 Vpp and no more than 1 W. Choose DC or AC coupling and set the trigger level in the trigger menu or from the browser.
One output to each oscilloscope
Run an SMA cable from an output to the Ext Trigger Input on the rear panel of each oscilloscope. The outputs deliver an 800 mVpp pulse with 400 mV offset into 50 Ω and need a 50 Ω load to ground, DC coupled. Siglent’s data sheet also allows an analog channel as the trigger input. Use cables of the same type and length, so every unit sees the edge at the same moment.
Set every oscilloscope to trigger on EXT
Trigger source EXT, type Edge, and a level in the middle of the pulse, around 0.4 V. The SDS6000L needs at least 200 mVpp on EXT and accepts up to 1.5 Vrms; EXT/5 divides the signal by five when a larger pulse is used.
Lock the sample clocks (optional)
Connect 10 MHz Out of the first oscilloscope to 10 MHz In of the second, its Out to the In of the third, and so on. On every unit that receives the clock set Utility › Menu › IO › Clock Source to External. All units then sample from one reference.
Put every unit on the network
Connect each oscilloscope and the SYN64-R to a Gigabit switch. The host reads every unit with SCPI, LabVIEW or the IVI driver; the LAN port is LXI compliant. For browser control of more than two instruments give each one its own VNC port (5900 to 5999). The SYN64-R has its own browser page for the trigger and output settings.
Calibrate the skew
Feed distributor outputs into the analog channels, measure the delay of each channel with its cable, and enter it as Deskew on that channel. Differences between the trigger cables are corrected on the SYN64-R itself: each group of eight outputs has its own delay, in 10 ps steps. Siglent specifies the skew between units as below 500 ps without this step and below 150 ps with it.
- Synchronization signal. A pulse or clock of 0.5 to 20 Vpp from the experiment, a generator or one of the oscilloscopes.
- SMA cables. One per instrument, same type and length, with the connector your trigger input needs at the far end.
- 10 MHz cables. One fewer than the number of oscilloscopes, if you lock the sample clocks.
- Gigabit switch and LAN cables. One port per oscilloscope, one for the SYN64-R and one for the host.
Application examples
A synchronization distributor is needed wherever more signals have to be captured at the same moment than one oscilloscope has channels. These are the set-ups it is used for.
Sensor and detector arrays
Hundreds of signals from one event, recorded on one time base: detector read-out, acoustic and ultrasonic arrays, structural tests.
Pulsed power, laser and accelerator diagnostics
A shot that happens once has to be caught on every channel at the same instant. The firing pulse goes into the distributor and every oscilloscope records the same shot.
Antenna arrays and multi-channel receivers
Phase and timing between many channels only mean something when all of them share one trigger and one sample clock.
Test racks with several instruments
The outputs are plain 800 mVpp pulses into 50 Ω, so one start signal can trigger oscilloscopes, generators and other instruments in the same rack.
Aligning the channels of the system
Siglent names this use in the data sheet: the 64 edges leave the distributor together, so they are the reference for measuring the delay of every channel and cable.
Triggers that need conditioning
A noisy or irregular start signal becomes a clean, defined pulse: trigger on a pulse width, hold off for a time or a number of events, and set the width and polarity of the output pulse.
How large can the system be?
| Oscilloscopes | Channels with 8-channel models | Channels with 4-channel models | Outputs used |
|---|---|---|---|
| 2 | 16 | 8 | 2 of 64 |
| 4 | 32 | 16 | 4 of 64 |
| 8 | 64 | 32 | 8 of 64 |
| 16 | 128 | 64 | 16 of 64 |
| 32 | 256 | 128 | 32 of 64 |
| 64 | 512 | 256 | 64 of 64 |
One SYN64-R serves every size in the table. Siglent specifies the jitter between units as below 250 ps rms (SDS6000L data sheet).
Specifications
| Inputs | 4 channels · SMA · 50 Ω · −10 to +10 V, 0.5–20 Vpp swing · DC or AC coupling (−3 dB at 20 Hz) · ≤ 1 W |
| Minimum input pulse width | 1 ns (Buff mode) · 3.2 ns (Normal mode) |
| Trigger | Rising / falling edge · positive / negative pulse width (3.2 ns resolution) · force trigger · level −10 to +10 V |
| Trigger hold-off | By time 3.2 ns to 30 s · by events 1 to 108 |
| Outputs | 64 channels in 8 groups of 8 · SMA · 800 mVpp swing with 400 mV DC offset into 50 Ω · load 50 Ω to ground, DC coupled |
| Output rise time | ≤ 500 ps |
| Jitter | 1 ps typical |
| Skew | 30 ps typical, 50 ps maximum, over the full operating temperature range |
| Channel delay adjustment | Per group · Buff mode: 0–3 ns in 10 ps steps · Normal mode: 0–30 s in 7 ps steps |
| Output pulse | Buff mode: width follows the input · Normal mode: set width and polarity per group |
| Remote control | LAN (1000M, SCPI, web interface) · USB 2.0 device (USBTMC) |
| Power | 9–15 V DC, 4 A, from the supplied AC adapter |
| Size | 433.4 × 43 × 283.6 mm (W × H × D), 1U rack height |
| Environment | Operating 0 to 50 °C, 5–90% RH · storage −30 to 70 °C · altitude to 3048 m |
| Warranty | 3 years |
From the SYN64-R Data Sheet EN01A. Specifications apply after 30 minutes of operation at 18–28 °C; errors and omissions excepted.
SYN64-R versus the SYN64
Both fan one synchronization signal out to 64 channels. The original SYN64 remains available; the -R adds inputs, a trigger engine, per-group timing and remote control.
| Feature | SYN64 | SYN64-R |
|---|---|---|
| Inputs | 1 | 4, selectable source |
| Trigger types | Edge, level set by potentiometer | Edge, pulse width, force; menu-set level, hold-off by time or events |
| Output rise time | 300 ps typical | ≤ 500 ps |
| Skew | 30 ps in a group, 140 ps typical between groups | 30 ps typical, 50 ps maximum, all channels |
| Delay / polarity per group | — | Yes, 10 ps or 7 ps steps |
| Output pulse width | Follows the input | Follows the input (Buff) or set per group (Normal) |
| Remote control | — | LAN (SCPI, web UI) and USB |
| Display | — | LCD with menu, keys and knob |
| Power | 12 W consumption | 9–15 V DC, 4 A, adapter supplied |
| Housing | 1U, 434.8 × 43 × 285.4 mm | 1U, 433.4 × 43 × 283.6 mm |
Around the unit
Front: display, keys and knob, the four SMA inputs, LAN, USB and power switch. Rear: the 64 SMA outputs, DC input and fuse. Supplied with the AC adapter and power cord.




Downloads: documents, firmware and drivers
The SYN64-R data sheet, and everything for the SDS6000L oscilloscopes it synchronizes. The links always open the current edition on Siglent’s server.
Siglent has not published a separate firmware file or programming guide for the SYN64-R (checked on 23 November 2026). The unit is set from its front panel, its browser page or over LAN and USB.

Planning a multi-unit acquisition system?
Tell us the channel count, bandwidth and cable runs. We will configure the SDS6000L units, the SYN64-R and the reference-clock chain as one quotation.