Raises the analogue bandwidth from 350 MHz to 500 MHz by key — no hardware change.

A bandwidth upgrade is a licence, not a board swap. The analogue front end is already capable of the higher bandwidth; the licence removes the limit in firmware. The instrument stays on your bench, keeps its serial number and calibration history, and the change takes effect as soon as the code is entered.

Siglent SDS5000X oscilloscope
The SDS5000X series, 4-channel model shown. The 2-channel models are no longer made.

What this option does

What it does

A software key that turns a 350 MHz SDS5000X into the 500 MHz model — the SDS5034X into the SDS5054X, or on the 2-channel instrument the SDS5032X into the SDS5052X. It is entered on the instrument; no part is changed. One specification stays as it was: Siglent’s data sheet notes that an upgraded instrument keeps the offset range of the 350 MHz model.

What you use it for

More bandwidth for faster edges and higher-frequency content, without replacing an instrument that is otherwise doing its job.

In practice

A bench bought for motor-drive work takes on a gate driver with nanosecond edges. The oscilloscope’s own rise time falls from 1.0 ns to 0.7 ns, so less of the edge on screen belongs to the instrument — and it keeps its probes, its calibration history and its place on the bench.

Before you order

⚠ This is as far as a 350 MHz SDS5000X goes: Siglent do not offer a 1 GHz upgrade for the 350 MHz model. The supplied 500 MHz passive probes match this upgrade.

The upgrade at a glance

From the SDS5000X data sheet.

Upgrade350 MHz → 500 MHz
ForSDS5032X (no longer made)
BecomesSDS5052X (no longer made)
Rise time (50 Ω)1.0 ns → 0.7 ns
Channels2 analogue
Stays as it wasThe offset range of the SDS5032X (data sheet note)
Further upgradeNone — a 350 MHz model cannot be upgraded to 1 GHz
Supplied probesSP3050A, 500 MHz, one per channel — they match the upgrade
DeliveryLicence key against the instrument’s serial number

Compatibility

This key fits exactly one instrument. Find yours in the table: the row is the channel count, the column the bandwidth it has today.

Channels350 MHz500 MHz1 GHz
4-channel
2-channel
SDS5032X (no longer made)
Fits this key
SDS5052X (no longer made)
Becomes this model
SDS5102X (no longer made)

The 2-channel SDS5032X, SDS5052X and SDS5102X are no longer made; their keys remain available. The SDS5000X HD is a different series with its own option keys.

Related options and accessories

Questions about SDS-5000X-2BW05

Which instrument does SDS-5000X-2BW05 fit?

The SDS5032X — the 2-channel, 350 MHz model. After the key is entered it is the SDS5052X. The keys are specific to the channel count, so order the 2-channel key for a 2-channel instrument. The 2-channel models are no longer made, but their keys remain available.

Can I upgrade to 1 GHz later?

No. Siglent do not offer a 1 GHz upgrade for the 350 MHz model — 500 MHz is as far as it goes. If you expect to need 1 GHz, a SDS5102X is the instrument to look at.

Is the upgraded instrument identical to a SDS5052X?

In bandwidth, yes. Siglent’s data sheet notes one difference: an instrument upgraded from 350 MHz keeps the offset range of the SDS5032X.

Do I need different probes after the upgrade?

No. The SP3050A probes supplied with the instrument are rated 500 MHz, which matches this upgrade.

Does the upgrade affect calibration?

The instrument keeps its serial number and its calibration history. If your quality system requires a calibration after a specification change, we can arrange ISO or DKD/DAkkS calibration.

How is the licence delivered?

Supplied as a licence key issued against the instrument's serial number. There is no hardware to fit and nothing to return: the code is entered in the instrument's own menu and the function is available immediately, on the instrument you already own. Add the instrument’s serial number to your order, or send it to us afterwards — the key is issued against it.

Can I return a licence?

Software licences and activation keys are delivered electronically and are excluded from the 14-day EU return right once the key has been issued. If you are unsure which key you need, ask us first — with your serial number we can confirm it.

Not sure this is the right key?

Send us your serial number and what you want to measure. We will confirm the exact option before you order.