Siglent SDS5000HD-ARINC license option
Unlocks the SDS5000HD-ARINC option for ARINC 429 trigger and decode, 12.5 to 100 kbps. For the SDS5000X HD
SDS5000HD-ARINC — ARINC 429 trigger & decode
ARINC 429 trigger and decode, 12.5 to 100 kbps.
Supplied as a licence key issued against the instrument's serial number. There is no hardware to fit and nothing to return: the code is entered in the instrument's own menu and the function is available immediately, on the instrument you already own.

What this option does
What it does
Triggers on word start or end, a label, a label plus data, an error or individual bits, and decodes ARINC 429 at 12.5 to 100 kbps with a 1 to 20 % rate tolerance, in L/SDI/D/SSM, L/D/SSM or L/D word formats.
What you use it for
ARINC 429 is a one-way broadcast bus, so the practical question is usually whether a particular label is present, correctly formed and arriving at the right rate.
In practice
During integration a display ignores altitude data. Triggering on the altitude label shows the words are present and well formed but arriving at half the expected rate — which points at the transmitting unit.
Decoding uses analogue channels C1 to C8 only, not the SPL2016’s digital channels.
Trigger and decode details
From the SDS5000X HD data sheet.
| Trigger types | Word start, Word end, Label, Label + Data, Error, Any bit, Any bit of 0, Any bit of 1 |
| Bit rate | 12.5 to 100 kbps, tolerance 1–20 % |
| Word formats | L/SDI/D/SSM, L/D/SSM, L/D |
| Decode from | Analogue channels C1–C8 only |
| Decoders at once | 2, full duplex |
| Standard on every SDS5000X HD | I²C, SPI, UART, CAN, LIN — no key needed |
Compatibility
The option runs on every SDS5000X HD model, at every bandwidth and channel count.
| Channels | 350 MHz | 500 MHz | 1 GHz |
|---|---|---|---|
| 4-channel | Compatible | Compatible | Compatible |
| 6-channel | SDS5036X HD (on request) Compatible | SDS5056X HD (on request) Compatible | SDS5106X HD (on request) Compatible |
| 8-channel | Compatible | Compatible | Compatible |
The SDS5000L low-profile models have their own option keys. The 6-channel models are supplied on request.
Related options and accessories
Questions about SDS5000HD-ARINC
Can I decode from the SPL2016 logic probe?
No. ARINC 429 decodes from the analogue channels C1 to C8 only.
Which protocols are already included?
I²C, SPI, UART, CAN and LIN trigger and decode are standard on every SDS5000X HD. CAN FD, FlexRay, I²S, MIL-STD-1553B, SENT, ARINC 429 and Manchester are keys. Up to two decoders run at the same time.
How is the licence delivered?
Supplied as a licence key issued against the instrument's serial number. There is no hardware to fit and nothing to return: the code is entered in the instrument's own menu and the function is available immediately, on the instrument you already own. Add the instrument’s serial number to your order, or send it to us afterwards — the key is issued against it.
Can I return a licence?
Software licences and activation keys are delivered electronically and are excluded from the 14-day EU return right once the key has been issued. If you are unsure which key you need, ask us first — with your serial number we can confirm it.
Not sure this is the right key?
Send us your serial number and what you want to measure. We will confirm the exact option before you order.