Siglent SNA5022A 100 kHz ~ 13.5 GHz Vector Network Analyzer
The SIGLENT SNA5022A is the 100 kHz ~ 13.5 GHz Vector Network Analyzer with support for 2 ports scattering-parameter, differential-parameter, and time-domain parameter measurements.
Purchase a new SNA5000A instrument and select one free analysis option for your application.
The Siglent SNA5022A 9 kHz - 13.5 GHz VNA is a effective instrument for determining the Q-factor, bandwidth and insertion loss of a filter, It features impedance conversion, movement of measurement plane, limit testing, ripple test, fixture simulation and adapter removal / insertion adjustments. The SNA5022A hase five sweep types: Linear-Frequency mode, Log-Frequency mode, Power-Sweep mode, CW-Time mode and Segment-Sweep mode. The SNA5000A series VNAs also support scattering-parameter correction of SOLT, SOLR, TRL, Response and Enhanced Response for increased flexibility in R&D and manufacturing applications.
SNA Multi-window display:
Enhanced Time-Domain analysis(TDR)
Features
- Frequency range: 9 kHz - 13.5 GHz
- Frequency resolution: 1 Hz
- Level resolution: 0.05 dB
- Range of IFBW: 10 Hz~3 MHz
- Setting range of output level: -55 dBm ~ +10 dBm
- Dynamic range: 125 dB
- Types of calibration: Response calibration, Enhanced Response calibration, Full-one port
calibration, Full-two port calibration, Full-three port calibration, Full-four port
calibration, TRL calibration - Types of measurement: Scattering-parameter measurement, differential-parameter measurement,
receiver measurement, time-domain parameter analysis, limit test, ripple test,
impedance conversion, fixture simulation, adapter removal/insertion - Support Bias-Tees
- Interface: LAN, USB Device, USB Host(USB-GPIB)
- Remote control: SCPI/Labview/IVI based on USB-TMC/VXI-
- 11/Socket/Telnet/WebServer
- 12.1-inch touch screen
- Video output: HDMI
Model | SNA5002A SNA5004A |
SNA5012A SNA5014A |
SNA5022A | SNA5032A |
---|---|---|---|---|
Frequency Range | 9 kHz~4.5 GHz | 9 kHz~8.5 GHz | 100kHz-13.5GHz | 100kHz-26.5GHz |
Ports | 2/4 | 2/4 | 2 | 2 |
Frequency resolution | 1 Hz | |||
Level resolution | 0.05 dB | |||
Range of IFBW | 10 Hz~3 MHz | |||
Setting range of output level | -55 ~ +10 dBm | |||
Dynamic Range | 125 dB | |||
Interface | LAN, USB Device, USB Host(USB-GPIB) | |||
Remote control | SCPI/Labview/IVI based on USB-TMC/VXI-11/Socket/Telnet/WebServer | |||
Display | 12.1-inch touch screen | |||
Video output | HDMI | |||
Types of calibration | Response calibration, Enhanced Response calibration, Full-one port calibration, Full-two port calibration, Full-three port calibration, Full-four port calibration, TRL calibration | |||
Types of measurement | Scattering-parameter measurement, differential-parameter measurement, receiver measurement, time-domain parameter analysis, limit test, ripple test, impedance conversion, fixture simulation, adapter removal / insertion, enhanced time-domain parameter analysis (TDR),spectrum analysis, frequency offset, scalar mixer measurement |
Standard Accessories:
Optional Accessories:
VNA Calibration Kits
Enhanced Time Domain Reflectometer (SNA5000-TDR)
Basic Time-Domain analysis
(SNA5000-TDA)
Spectrum analysis function option
(SNA5000-SA)
Scalar mixer measurement option
(SNA5000-SMM)
High performance reference source
(SNA5000-HPR)
Siglent
V26-N35MN35F-25IN
Cable
Siglent
V26-N35FA35F-25IN
Cable
N(M)-N(M) cable,
100 cm,18 GHz
N(M)-SMA(M) cable,
100cm,18 GHz